- admin node
- installing software
- Installing SMC for Altix ICE Admin Node Software
- avoiding out of memory occurrences
- How To Avoid Out of Memory Occurrences on SLES11 and PBS Pro
- backing up and restoring the system data base
- Backing up and Restoring the System Database
- baseboard management controller (BMC)
- Four-tier, Hierarchical Framework
- basic system building blocks
- Basic System Building Blocks
- batch service node
- Batch Service Node
- blademond daemon
- blademond Command For Automatic Blade Discovery
- boot order
- service nodes
- Shutting Down and Booting
- C3 commands
- C3 Commands
- C4 administrative interface
- cadmin
- cadmin: SMC for Altix ICE Administrative Interface
- cadmin command
- cadmin: SMC for Altix ICE Administrative Interface
- set service node boot order
- cadmin: SMC for Altix ICE Administrative Interface
- cascading dual-boot
- Cascading Dual-Boot
- cattr command
- Setting up Local Storage Space for Swap and Scratch Disk Space
- changing the dhcp option code number
- Installing Software on the Rack Leader Controllers and Service
Nodes
- changing the global default password
- Configuring Factory-installed SGI Altix ICE System
- changing the size of per-node swap space
- Changing the Size of Per-node Swap Space
- changing the size of /tmp
- Changing the Size of /tmp on Compute Nodes
- chassis management control (CMC)
- Chassis Management Control (CMC) Blade
- chassis management control (CMC) blade
- embedded Ethernet switches
- Gigabit Ethernet (GigE) and 10/100 Ethernet Connections
- RJ45 connections
- Gigabit Ethernet (GigE) and 10/100 Ethernet Connections
- chassis management controller (CMC)
- Four-tier, Hierarchical Framework
- cimage command
- cimage Command
- cinstallman command
- cinstallman Command
- cluster manager software
- System Discovery, Installation, and Configuration
- cminfo command
- cminfo Command
- cnodes command
- cnodes Command
- commands
- cadmin
- cadmin: SMC for Altix ICE Administrative Interface
- cattr
- Setting up Local Storage Space for Swap and Scratch Disk Space
- cimage
- cimage Command
- cinstallman
- cinstallman Command
- cminfo
- cminfo Command
- cnodes
- cnodes Command
- configure-cluster
- configure-cluster Command Cluster Configuration
Tool
- console
- Console Management
- cpasswd
- Configuring Factory-installed SGI Altix ICE System
- cpower
- Power Management Commands
- crepo
- crepo Command
- dbdump
- dbdump Command
- discover
- discover Command
- discover-rack
- blademond daemon
- blademond Command For Automatic Blade Discovery
- mysqldump
- Backing up and Restoring the System Database
- smc-info-gather
- smc-info-gather Command
- compute node
- Compute Node
- software
- customizing
- Customizing Software On Your SGI Altix ICE System
- customizing for additional network interfaces
- Compute Node Per-Host Customization for Additional Network Interfaces
- services turned off
- Compute Node Services Turned Off by Default
- compute node software
- Software Image Management
- Configure backup DNS server
- Configure the Backup DNS Server
- configure-cluster command
- configure-cluster Command Cluster Configuration
Tool
- configuring factory-installed SGI Altix ICE system
- RHEL
- Configuring Factory-installed SGI Altix ICE System
- SLES
- Configuring Factory-installed SGI Altix ICE System
- configuring service nodes
- Configuring the Service Node
- configuring the service node
- for DNS
- Service Node Configuration for DNS
- for NAT
- Service Node Configuration for NAT
- for NFS
- Service Node Configuration for NFS
- for NIS for the house network
- Service Node Configuration for NIS for the House Network
- using external DNS for compute node name resolution
- Using External DNS for Compute Node Name Resolution
- conserver console management package
- Console Management
- conserver console software package
- Console Management
- console management
- Console Management
- cpasswd command
- Configuring Factory-installed SGI Altix ICE System
- cpower command
- Power Management Commands
- creating user accounts
- Creating User Accounts
- crepo command
- crepo Command
- database for the system back up and restore procedure
- Backing up and Restoring the System Database
- dbdump command
- dbdump Command
- DHCP option code
- Installing Software on the Rack Leader Controllers and Service
Nodes
- dhcp options
- changing
- Installing Software on the Rack Leader Controllers and Service
Nodes
- disabling InfiniBand switch monitoring
- InfiniBand Configuration
- disabling the iSCSI swap device
- Enabling or Disabling the Compute Node iSCSI Swap Device
- discover command
- discover Command
- discover rack command
- blademond Command For Automatic Blade Discovery
- discovering compute nodes
- Discovering Compute Nodes
- DNS
- service node configuration
- Service Node Configuration for DNS
- Embedded Support Partner (ESP)
- Setting up the Embedded Support Partner
- ensabling the iSCSI swap device
- Enabling or Disabling the Compute Node iSCSI Swap Device
- firmware management
- Firmware Management
- fwmgrd daemon
- Firmwware Manager Daemon (fwmgrd)
- license requirement
- License Requirement
- terminology
- Terminology
- gateway service node
- Gateway Service Node
- getting firmware information for all system nodes
- Getting Firmware Information for All System Nodes
- grub boot-loader
- Restoring the grub Boot-loader on a Node
- HAE with HA-RLC
- HAE with HA-RLC
- Installing the Altix ICE Admin Node for a HA-RLC Cluster
- hardware hierarchy
- Four-tier, Hierarchical Framework
- hardware overview
- Basic System Building Blocks
- HA-RLC
- administrative resource migration
- Administrative Resource Migration
- confirm compute node set up
- Confirm Boot of Compute Nodes
- confirm initial set up
- Confirm Initial HA-RLC Setup
- confirm installation
- Confirm HAE After HA-RLC Boot
- create repositories
- Create SLES11 SP1 and HAE Repositories
- crm_gui utility
- crm_gui Utility
- crm_mon command line utility
- crm_mon Command Line Utility
- discover racks
- Discover HA--RLC Racks
- HAE
- Installing the Altix ICE Admin Node for a HA-RLC Cluster
- HAE documentation
- SLES11 SP1 High Availability Extension (HAE) Documentation
- Hawk browser interface
- Hawk Browser Interface
- initial cluster configuration
- Initial Cluster Configuration with HA-RLC
- monitor compute node set up
- Monitor Compute Node Set up
- monitor installation
- Monitor HA-RLC Installation
- monitor rack status
- Monitor Rack HAE Status
- network changes
- HA-RLC Networking Changes
- replace the HA-RLC instance
- Replace a HA-RLC
- sequential discovery of HA-RLC
- Sequential Discovery of HA-RLC
- update repositories
- Update Repositories Example
- HA-RLC naming
- HA-RLC Naming
- hierarchy of nodes
- Four-tier, Hierarchical Framework
- High Availability Extension (HAE) documentation
- SLES11 SP1 High Availability Extension (HAE) Documentation
- high availability extension documentation
- High Availability Extension Documentation
- high availability extension, virtualization, updates
- HAE, Virtualization and Updates installation
- home directories on NAS
- Home Directories on NAS
- individual rack unit (IRU)
- Individual Rack Unit
- InfiniBand configuration
- InfiniBand Configuration
- disabling InfiniBand switch monitoring
- InfiniBand Configuration
- InfiniBand fabric
- InfiniBand Fabric
- configuration and operation overview
- InfiniBand Fabric Management Configuration and Operation Overview
- diagnostic commands
- ibdiagnet
- ibdiagnet Command
- ibnetdiscover
- ibnetdiscover Command
- ibstat
- ibstat and ibstatus Commands
- ibstatus
- ibstat and ibstatus Commands
- perfquery
- perfquery Command
- management
- InfiniBand Fabric Management
- management tool graphical user interface (GUI)
- InfiniBand Management Tool Graphical User Interface
- routing engine variables
- Network Topology
- sgifmcli command
- Fabric Component sgifmcli Command
- utilities and diagnostics
- Useful Utilities and Diagnostics
- Infiniband network
- InfiniBand Network
- initial configuration of a RHEL 6 admin node
- Initial Configuration of a RHEL 6 Admin Node
- installing SLES11 on the admin node
- Installing SLES11 on the Admin Node
- installing SMC for Altix ICE patches
- Installing SMC for Altix ICE Patches and Updating SGI Altix ICE
Systems
- installing software on rack leader controllers
- Installing Software on the Rack Leader Controllers and Service
Nodes
- installing software on service nodes
- Installing Software on the Rack Leader Controllers and Service
Nodes
- interconnect verification tool (IVT)
- Networks Overview
- introduction
- Basic System Building Blocks
- inventory verification tool (IVT)
- Inventory Verification Tool
- kdump utility
- system dump
- kdump Utility
- traceback
- kdump Utility
- keeping time synchronized
- Keeping System Time Synchronized
- local storage for swap and scratch disk space
- Setting up Local Storage Space for Swap and Scratch Disk Space
- login service node
- Login Service Node
- main power
- Power Supply
- memory
- out of memory adjustments
- How To Avoid Out of Memory Occurrences on SLES11 and PBS Pro
- monitoring system metrics with Performance Co-Pilot
- Monitoring System Metrics with Performance Co-Pilot
- MPI
- default configuration
- InfiniBand Fabric
- multiroot
- Partition Layout for Admin, Leader, and Service Nodes with Multiroot
- mysqldump command
- Backing up and Restoring the System Database
- NAS home directories
- Home Directories on NAS
- NAT
- configuring the service node
- Service Node Configuration for NAT
- network interface naming conventions
- Network Interface Naming Conventions
- Hostnames
- hostnames
- Hostnames
- Infiniband network
- InfiniBand Network
- non-resolvable Names
- Non-resolvable Names
- system component names
- System Component Names
- VLAN_1588
- VLAN_1588 Network Connections
- VLAN_BMC
- VLAN_BMC Network Connections
- VLAN_GBE
- VLAN_GBE Network Connections
- VLAN_Head
- VLAN_Head Network Connections
- network time protocol (NTP)
- Keeping System Time Synchronized
- networks
- Gigabit Ethernet (GigE) and 10/100 Ethernet connections
- Gigabit Ethernet (GigE) and 10/100 Ethernet Connections
- InfiniBand fabric
- InfiniBand Fabric
- network interface naming conventions
- Network Interface Naming Conventions
- overview
- Networks
- virtual local area networks (VLANs)
- VLANs
- NFS
- service node configuration
- Service Node Configuration for NFS
- NIS
- service node configuration for the house network
- Service Node Configuration for NIS for the House Network
- node replacement procedure
- Node Replacement Procedure for a Cold Spare Admin, Leader, and
Service Nodes
- nodes
- batch service node
- Batch Service Node
- compute
- Compute Node
- gateway
- Gateway Service Node
- login service
- Login Service Node
- rack leader controller
- leader node
- Rack Leader Controller
- storage service
- Storage Service Node
- system admin controller
- admin node
- System Admin Controller
- out of memory occurrences
- How To Avoid Out of Memory Occurrences on SLES11 and PBS Pro
- overview
- SGI Altix ICE System Overview
- pdsh and pdcp utilities
- pdsh and pdcp Utilities
- Performance Co-Pilot
- Monitoring System Metrics with Performance Co-Pilot
- PMIE temperature feature
- Turning Off the temperature.pmie Feature
- power management
- cpower command
- Power Management Commands
- IPMI-style commands
- IPMI-style Commands
- IRU, rack, and system domains
- IRU, Rack, and System Domains
- operation on nodes
- Operations on Nodes
- shutting down and booting
- Shutting Down and Booting
- boot order
- Shutting Down and Booting
- power supply
- BMC
- Power Supply
- CMC
- Power Supply
- compute blades
- Power Supply
- main power
- Power Supply
- rack leader controller
- Four-tier, Hierarchical Framework
- Rack Leader Controller
- high availability
- administrative resource migration
- Administrative Resource Migration
- compute node boot requirement
- Compute Node tmpfs Boot Requirement
- confirm compute node set up
- Confirm Boot of Compute Nodes
- confirm HA-RLC set up
- Confirm Initial HA-RLC Setup
- confirm installaton
- Confirm HAE After HA-RLC Boot
- create repositories
- Create SLES11 SP1 and HAE Repositories
- crm_gui utility
- crm_gui Utility
- crm_mon command line utility
- crm_mon Command Line Utility
- discover racks
- Discover HA--RLC Racks
- documentation
- SLES11 SP1 High Availability Extension (HAE) Documentation
- HAE overview
- High Availability Extension
- HAE with HA-RLC
- HAE with HA-RLC
- hardware requirements
- Hardware Requirements
- Hawk browser interface
- Hawk Browser Interface
- initial cluster configuration
- Initial Cluster Configuration with HA-RLC
- installing admin node
- Installing the Altix ICE Admin Node for a HA-RLC Cluster
- monitor compute node set up
- Monitor Compute Node Set up
- monitor installation
- Monitor HA-RLC Installation
- monitor rack HAE status
- Monitor Rack HAE Status
- naming
- HA-RLC Naming
- network changes
- HA-RLC Networking Changes
- overview
- Rack Leader Controller High Availability Solution
- physical connections
- Physical Connections
- replace HA-RLC
- Replace a HA-RLC
- sequential discovery of HA-RLC
- Sequential Discovery of HA-RLC
- software requirements
- Software Requirements
- update repositories
- Update Repositories Example
- rack leader controller high availability solution
- Rack Leader Controller High Availability Solution
- See Also rack leader controller high availability
- RAID utility
- RAID Utility
- redundant management network
- Redundant Management Network
- restoring the grub boot-loater
- Restoring the grub Boot-loader on a Node
- scratch space
- Setting up Local Storage Space for Swap and Scratch Disk Space
- service node boot order
- Shutting Down and Booting
- service node discovery, installation, and configuration
- Service Node Discovery, Installation, and Configuration
- setting up a NIS Server
- Setting Up a NIS Server for Your Altix ICE System
- setting up an NFS home server on a service node
- Setting Up an NFS Home Server on a Service
Node for Your Altix ICE System
- partitioning, creating, and mounting filesystems
- Partitioning, Creating, and Mounting Filesystems
- setting up local storage space for swap and scratch disk space
- Setting up Local Storage Space for Swap and Scratch Disk Space
- setting up serial over LAN connection
- Gigabit Ethernet (GigE) and 10/100 Ethernet Connections
- setting up the Embedded Support Partner (ESP)
- Setting up the Embedded Support Partner
- shelf spare replacement
- Cold Spare Admin or Leader Node Availability
- booting a replacement system
- Migrating to a Cold Spare: Booting for the First Time on the Migrated
Node
- importing the disk volumes
- Migrating to a Cold Spare: Importing the Disk Volumes
- installing hardware
- Identify the Failed Unit and Unplug all Cables
- smc-info-gather command
- smc-info-gather Command
- storage service node
- Storage Service Node
- switching compute nodes to a tmpfs root
- Switching Compute Nodes to a tmpfs Root
- system admin contoller
- high availability
- SMC licenses
- SMC Licenses
- system admin controller
- Four-tier, Hierarchical Framework
- System Admin Controller
- high availability
- Overview
- accessing GUI and HA cluster account
- Accessing crm_gui and the hacluster
Account
- allocate physical node IP addresses
- Allocate Physical Node IP Addresses with SGI Management Center
- configure SGI helper scripts
- Configure the SGI Helper Scripts
- customization
- High Availability Customization
- documentation
- High Availability Extension Documentation
- HAE, Virtualization and Updates installation
- external storage configuration
- External Storage Configuration
- hardware requirements
- Hardware Requirements
- install SGI helper scripts
- Install SGI Helper Scripts (sac-ha Package)
- migrating to virtual admin node live
- Migrating a Virtualized Admin Node Live
- network configuration
- Network Configuration
- physical node BMC configuration
- Physical Node BMC Configuration
- physical requirements
- Physical Connections
- software requirements
- Software Requirements
- virtual admin guest service
- Virtual Admin Guest Service
- virtual admin node resource
- Virtual Admin Node Resource
- virtual machine installation
- Virtual Machine Installation
- installing software
- Installing SMC for Altix ICE Admin Node Software
- system component names
- System Component Names
- system firmware
- System Firmware
- BIOS version interrogation
- BIOS Version Interrogation
- BMC revision interrogation
- BMC Revision Interrogation
- CMC revision interrogation
- CMC Version Interrogation
- getting firmware information for all system nodes
- Getting Firmware Information for All System Nodes
- InfiniBand version interrogation
- InfiniBand Version Interrogation
- system management software
- SGI Altix ICE System Overview
- system monitoring
- operation
- Accessing the Ganglia System Monitor
- overview
- System Monitoring Overview
- with Performance Co-Pilot
- Monitoring System Metrics with Performance Co-Pilot
- monitoring SDR metrics
- Monitoring SDR Metrics
- system overview
- SGI Altix ICE System Overview
- Basic System Building Blocks
- temperature.pmie feature
- turning off
- Turning Off the temperature.pmie Feature
- temperature.pmie values
- adjusting
- Adjusting temperature.pmie Values
- troubleshooting
- Troubleshooting
- cminfo
- cminfo Command
- dbdump
- dbdump Command
- smc-info-gather
- smc-info-gather Command
- troubleshooting service node configuration for NAT
- Troubleshooting Service Node Configuration for NAT
- user accounts
- creating
- Creating User Accounts
- viewing the compute node read-write quotas
- Viewing the Compute Node Read-Write Quotas
- virtual local area networks (VLANs)
- VLANs
- VLAN_1588
- VLANs
- VLAN_BMC
- VLANs
- VLAN_GBE
- VLANs
- VLAN_HEAD
- VLANs
- VLAN_1588 network connections
- VLAN_1588 Network Connections
- VLAN_BMC network connections
- VLAN_BMC Network Connections
- VLAN_GBE network connections
- VLAN_GBE Network Connections
- VLAN_Head network connections
- VLAN_Head Network Connections